Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

SUMMIT HEALTH AND REHAB CENTER

LYNCHBURG, VA · 120 certified beds · Last Life Safety survey May 1, 2025

CMS Certification Number 495381 · first certified September 2004

Ownership

Operated by HILL VALLEY HEALTHCARE · For profit - Corporation

  • Ownership changed November 1, 2021 (change of ownership)from CENTRA HEALTH, INC
14
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
4
Tags cited more than once
Across separate surveys
10
Inspection & testing records
Of the citations on file

Position within VA

14 citations — more than 65% of the 289 certified nursing homes in VA. Compared within VA rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Improvingfewer citations at the latest survey than at its earlier surveys in the window.

The latest survey found 1 citation; the earlier surveys in the window averaged 6.5. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens December 2027 — about 14 months from now. This facility’s last Life Safety survey was May 2025. Facilities in VA are typically surveyed 31–43 months after the last one (median 37), measured over 125 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about SUMMIT HEALTH AND REHAB CENTER

One email when it happens. No account; stop it any time with one click.

Which alerts

4 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Physical environment (health survey)

3 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 14 Life Safety citations above. The Physical Environment Index

  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
  • F-0880 Provide and implement an infection prevention and control program.

How that compares

Citations on file over three years

Compared with the median facility in VA, and nationally. Surveyors differ markedly between states, so the VA figure is the meaningful one.

This facility14VA median10National median11
Citations on file over three years, compared
MeasureCitations
This facility14
Median facility in VA10
Median facility nationally11

Survey history

Citations at each Life Safety survey
72019-1062022-0412025-05
Citations at each Life Safety survey
Survey dateCitations
October 24, 20197
April 21, 20226
May 1, 20251

Most-cited tags

Most-cited tags at this facility
K-05112K-03532K-03632K-07612K-03521K-02931K-05311K-03451
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0511Have properly installed electrical wiring and gas equipment.22022-04-21
K-0353Inspect, test, and maintain automatic sprinkler systems.22022-04-21
K-0363Install corridor and hallway doors that block smoke.22022-04-21
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.22025-05-01
K-0352Properly install and monitor supervisory attachments on automatic sprinkler systems.12022-04-21
K-0293Have properly located and lighted "Exit" signs.12019-10-24
K-0531Have elevators that firefighters can control in the event of a fire.12019-10-24
K-0345Have approved installation, maintenance and testing program for fire alarm systems.12022-04-21

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 7
  • Services Deficiencies 3
  • Egress Deficiencies 2
  • Miscellaneous Deficiencies 2
Citations by CMS category
CategoryCitations
Smoke Deficiencies7
Services Deficiencies3
Egress Deficiencies2
Miscellaneous Deficiencies2

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

May 1, 2025 — 1 citation

Citations issued on May 1, 2025
TagWhat the surveyor checksStatus
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (July 27, 2025)

April 21, 2022 — 6 citations

Citations issued on April 21, 2022
TagWhat the surveyor checksStatus
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (July 15, 2022)
K-0352Properly install and monitor supervisory attachments on automatic sprinkler systems.Waiver has been granted (December 1, 2022)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (July 15, 2022)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (July 15, 2022)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (July 15, 2022)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Waiver has been granted (July 15, 2022)

October 24, 2019 — 7 citations

Citations issued on October 24, 2019
TagWhat the surveyor checksStatus
K-0223Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.Deficient, Provider has date of correction (December 16, 2019)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (December 16, 2019)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (December 16, 2019)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (December 16, 2019)
K-0363Install corridor and hallway doors that block smoke.Deficient, Provider has date of correction (December 16, 2019)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (December 16, 2019)
K-0531Have elevators that firefighters can control in the event of a fire.Deficient, Provider has date of correction (December 16, 2019)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.