Federal nursing home survey record · CMS-certified nursing home· Not a state assisted-living licensing record

Edenbrook Omro

Omro, WI · 50 certified beds · Last Life Safety survey September 10, 2025

CMS Certification Number 525406 · first certified March 1987

Ownership

Operated by EDEN SENIOR CARE · For profit - Limited Liability company

  • Ownership changed December 4, 2018 (change of ownership)to OMRO CARE CENTER from OMRO HEALTHCARE, LLC
27
Citations on file
Rolling three-year window
3
Life Safety surveys
In the same window
7
Tags cited more than once
Across separate surveys
17
Inspection & testing records
Of the citations on file

Position within WI

27 citations — more than 77% of the 323 certified nursing homes in WI. Compared within WI rather than nationally because which state a facility is in explains about 30% of the variation in citation counts between facilities, while bed count explains under 1%. State survey agencies differ far more than the buildings do. How this is calculated

Slippingmore citations at the latest survey than at its earlier surveys in the window.

The latest survey found 15 citations; the earlier surveys in the window averaged 6. With 3 surveys on file this is a direction of travel, not a conclusion.

When is the next survey likely?

The window opens October 2026 — about 1 month from now. This facility’s last Life Safety survey was September 2025. Facilities in WI are typically surveyed 13–15 months after the last one (median 14), measured over 516 consecutive surveys in the last two years of CMS records.

A range the record supports, not a prediction of a date. State agencies vary widely — from about 11 months in Pennsylvania to three years in Maryland. How the window is measured

Get an email about Edenbrook Omro

One email when it happens. No account; stop it any time with one click.

Which alerts

5 inspection-and-testing tags have been cited here at more than one survey. Nationally, that pattern is common: about three quarters of cited facilities have at least one repeated tag, and half of the facilities ever cited for sprinkler inspection and testing are cited for it again. A repeat is usually a recordkeeping gap rather than a new hazard.

Emergency preparedness

1 of the 27 citations on file is Emergency Preparedness E-tags. E-tags are cited under 42 CFR §483.73 and concern the emergency plan, training, drills, communications and supplies. Nationally about half of certified facilities have at least one. The Emergency Preparedness Index

Physical environment (health survey)

5 physical-environment citations on the health survey. Cited by the health surveyors under Appendix PP, not the Life Safety Code surveyor: equipment in safe operating condition, the call system, bed rails, pest control, hazards, the environment. Counted separately from the 27 Life Safety citations above. The Physical Environment Index

  • F-0880 Provide and implement an infection prevention and control program.
  • F-0689 Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

How that compares

Citations on file over three years

Compared with the median facility in WI, and nationally. Surveyors differ markedly between states, so the WI figure is the meaningful one.

This facility27WI median17National median11
Citations on file over three years, compared
MeasureCitations
This facility27
Median facility in WI17
Median facility nationally11

Survey history

Citations at each Life Safety survey
32023-0692024-07152025-09
Citations at each Life Safety survey
Survey dateCitations
June 14, 20233
July 24, 20249
September 10, 202515

Most-cited tags

Most-cited tags at this facility
K-09183K-03533K-03213K-07122K-05112K-03452K-03412K-09231
Most-cited tags at this facility
TagWhat the surveyor checksTimes citedLast cited
K-0918Have generator or other power source capable of supplying service within 10 seconds.32025-09-10
K-0353Inspect, test, and maintain automatic sprinkler systems.32025-09-10
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.32025-09-10
K-0712Have simulated fire drills held at unexpected times.22025-09-10
K-0511Have properly installed electrical wiring and gas equipment.22025-09-10
K-0345Have approved installation, maintenance and testing program for fire alarm systems.22025-09-10
K-0341Install a fire alarm system that can be heard throughout the facility.22025-09-10
K-0923Have proper medical gas storage and administration areas.12025-09-10

What the citations cover

Citations by CMS category
  • Smoke Deficiencies 12
  • Services Deficiencies 4
  • Gas, Vacuum, and Electrical Systems Deficiencies 4
  • Egress Deficiencies 3
  • Other 4
Citations by CMS category
CategoryCitations
Smoke Deficiencies12
Services Deficiencies4
Gas, Vacuum, and Electrical Systems Deficiencies4
Egress Deficiencies3
Miscellaneous Deficiencies3
Emergency Preparedness Deficiencies1

Every citation on file

As published by CMS, newest survey first. Descriptions are CMS’s own wording.

September 10, 2025 — 15 citations

Citations issued on September 10, 2025
TagWhat the surveyor checksStatus
E-0041Implement emergency and standby power systems.Deficient, Provider has date of correction (October 3, 2025)
K-0211Keep aisles, corridors, and exits free of obstruction in case of emergency.Deficient, Provider has date of correction (October 9, 2025)
K-0222Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.Deficient, Provider has date of correction (October 3, 2025)
K-0293Have properly located and lighted "Exit" signs.Deficient, Provider has date of correction (October 3, 2025)
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (October 3, 2025)
K-0324Provide properly protected cooking facilities.Deficient, Provider has date of correction (October 9, 2025)
K-0341Install a fire alarm system that can be heard throughout the facility.Deficient, Provider has date of correction (October 9, 2025)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (October 3, 2025)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (October 3, 2025)
K-0355Properly select, install, inspect, or maintain portable fire extinguishes.Deficient, Provider has date of correction (October 3, 2025)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (October 9, 2025)
K-0521Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.Deficient, Provider has date of correction (October 9, 2025)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (October 3, 2025)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (October 3, 2025)
K-0923Have proper medical gas storage and administration areas.Deficient, Provider has date of correction (October 3, 2025)

July 24, 2024 — 9 citations

Citations issued on July 24, 2024
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (August 19, 2024)
K-0341Install a fire alarm system that can be heard throughout the facility.Deficient, Provider has date of correction (August 19, 2024)
K-0345Have approved installation, maintenance and testing program for fire alarm systems.Deficient, Provider has date of correction (September 5, 2024)
K-0353Inspect, test, and maintain automatic sprinkler systems.Waiver has been granted (August 29, 2024)
K-0511Have properly installed electrical wiring and gas equipment.Deficient, Provider has date of correction (August 19, 2024)
K-0522Have an externally vented heating system.Deficient, Provider has date of correction (August 19, 2024)
K-0712Have simulated fire drills held at unexpected times.Deficient, Provider has date of correction (August 19, 2024)
K-0761To conduct inspection, testing and maintenance of fire doors by qualified individuals.Deficient, Provider has date of correction (August 19, 2024)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (August 19, 2024)

June 14, 2023 — 3 citations

Citations issued on June 14, 2023
TagWhat the surveyor checksStatus
K-0321Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.Deficient, Provider has date of correction (June 16, 2023)
K-0353Inspect, test, and maintain automatic sprinkler systems.Deficient, Provider has date of correction (July 7, 2023)
K-0918Have generator or other power source capable of supplying service within 10 seconds.Deficient, Provider has date of correction (June 20, 2023)

Reflects the CMS posting of August 1, 2026. Surveys conducted in the last few months may not appear yet.